LEISTER LHS SYSTEM ~ Process Heaters
 
Features steplessly adjustable air temperature via integrated power electronics; power control via galvanic isolated 4-20mA interface for controller/PLC or built on rotary potentiometer; integrated device and heating-element protection assures heaters cannot be damaged by excessive temperature even in exceptional situations; an additional zero potential alarm contact ensures a high process reliability.
LHS SYSTEM 20S
Voltage

100

120
200
230
Power Consumption, kW
1
2
1
2
1
2
1
2
Max. Temperature, Celsius
600°
Min. Air Flow, LPM
200
300
200
300
200
300
200
300
Size Heating Tube, mm
36.5ø
Size Air Outlet, mm
19.5
Size L x W x H, mm
257 x 97 x 87
Weight, g
650
Protection Class II
                 
LHS SYSTEM 40S
Voltage

100

120
200
230
 
Power Consumption, kW
2
2
2
4
2
4
Max. Temperature, Celsius
600°
Min. Air Flow, LPM
300
300
300
400
300
400
Size L x W x H, mm
261 x 112 x 103
Weight, g
950
Size Heating Tube, mm
50ø
Size Air Outlet, mm
38ø
Protection Class II
                   
LHS SYSTEM 40L
Voltage, Three Phase
3 x 230
3 x 400
3 x 440
3 x 480
Power Consumption, kW
2
4
2
4
2
4
2
4
Max. Temperature, Celsius
600°
Min. Air Flow, LPM
300
400
300
400
300
400
300
400
Size L x W x H, mm
291 X 112 X 103
Weight, g
1050
Size Heating Tube, mm
50ø
Size Air Inlet, mm
38ø
Protection Class II
                   
LHS SYSTEM 60S
Voltage, Three Phase
3 x 230
3 x 400
3 x 440
3 x 480
Power Consumption, kW
4
6
4
6
4
6
4
6
Max. Temperature, Celsius
600°
Min. Air Flow, LPM
400
600
400
600
400
600
400
600
Size L x W x H, mm
379 x 114 x 137
Weight, g
3250
Size Heating Tube, mm
62ø
Size Air Inlet, mm
60ø
Protection Class I
                   
LHS SYSTEM 60L
Voltage, Three Phase
3 x 230
3 x 400
3 x 440
3 x 480
Power Consumption, kW
8
10
8 10 12 14 16
8 10 12 14 16
8 10 12 14 16
Max. Temperature, Celsius
600°
Min. Air Flow, LPM
1000-1800
Size L x W x H, mm
379 x 114 x 137
Weight, g
3750
Size Heating Tube, mm
92ø
Size Air Inlet, mm
60ø
Protection Class I
                   
For All Models
         
  Frequency, Hz
50 / 60
  Mark of Conformity
  Mark of Approval
  Certification Scheme
CCA
  2D and 3D drawings available.
View PDF Catalog
   
 
1 877 782 7747 | STAR Process Heat Systems LLC - Farmingdale, New Jersey | 732 282 1002